GasAlertMax
User Options Menu
The date and time displays in the
following order:
Day of the week (Monday = 1),
Hours (h),
Minutes,
Date
(D)
,
Month
(M)
,
Year
(Y)
.
Use H and G to adjust the time and
date to your local setting. Press C to
confirm each setting.
Sensor Enable/Disable Option
a Warning
Disabling an installed sensor configures the
detector to a one, two, or three-gas unit. No
protection is now provided for the gas targeted
by that sensor(s). Disabling a sensor should be
performed with extreme caution.
In the event a sensor fails, sensor disable can be used to
deactivate the sensor fail alarm. The sensor should be
replaced and enabled as soon as possible.
If a sensor is disabled, the detector still functions normally
with the remaining enabled sensors. The sensor can be
enabled again at any time.
To enable or disable a sensor,
press C when the LCD displays
toggLE H2S (CO, LEL, or O2)
SEn. For this example the H
2
S
sensor is toggled.
Note
Whenever you enter the sensor enable/disable
option, it toggles the option on or off (depending on
its current status).
The LCD displays whether the sensor is now on or off.