Black & Decker 6105-09 User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
3 4
Han® Q 5/0
BackboneDaisy Chain
H a n ® Q 5 /0
Han® Power Power Networks and Industrial Cabling
USER BENEFITS:
• compact design
fast-connect QuickLock
1)
technology for field
installation
• rated at 400 V
• for modular system design
Installation solutions
Technical characteristics
Applications
Contact inserts
Number of contacts 5 + PE
Electrical data
acc. to DIN EN 61 984 16 A 230/400 V 4 kV 3
Rated current 16 A
Rated voltage conductor - ground
230 V
Rated voltage conductor - conductor
400 V
Rated impulse voltage 4 kV
Pollution degree 3
Pollution degree 2 also 16 A 320/500 V 4 kV 2
Rated voltage acc. to UL/CSA
600 V
Material Polycarbonate
Limiting temperatures -40 °C … 125 °C
Mechanical working life
- Mating cycles ≥ 500
Contacts
Material copper alloy
Surface, hard silver plated 3 µm Ag
Crimp termination
- mm
2
0.14 … 2.5 mm
2
- AWG 26 … 14
PE as screw termination
- mm
2
up to 2.5 mm
2
- AWG 14
Hoods/housings
Plastic hoods/housings
Material Polycarbonate
Degree of protection acc. to
DIN EN 60 529 for coupled connector
IP 67
Point-to-point connection
Systems & machine applications
The HARTING Han® Q 5/0 product family offers a fully pluggable solution for distributed
power applications, for example to support modular system design. Pre-terminated
system cables and connectors with crimp terminals or Han-Quick Lock®
1)
termination
support a variety of installation solutions.
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 51 52

Comments to this Manuals

No comments